The award-winning TETCO ES4 Vertical Packaged unit is packed full of innovative ideas never before seen in a geothermal unit. The result is a geothermal system that provides the ultimate in comfort, savings and satisfaction.
Model | Capacity | Cooling | Heating | ||
---|---|---|---|---|---|
Btu/hr | EER | Btu/hr | COP | ||
TXT024 | Full Load | 27,200 | 20.3 | 19,800 | 4.3 |
Part Load | 21,400 | 29.1 | 16,600 | 4.8 | |
TXT036 | Full Load | 38,900 | 18.3 | 29,200 | 4.2 |
Part Load | 29,900 | 27.0 | 23,200 | 4.6 | |
TXT048 | Full Load | 49,000 | 17.1 | 38,200 | 3.9 |
Part Load | 37,400 | 24.1 | 29,700 | 4.3 | |
TXT060 | Full Load | 63,000 | 17.8 | 47,700 | 3.7 |
Part Load | 49,000 | 24.9 | 38,600 | 4.3 | |
TXT072 | Full Load | 71,100 | 17.1 | 55,900 | 3.6 |
Part Load | 57,500 | 23.0 | 46,700 | 4.1 |